Built to watch your network,
not to take it.
WatchMyTech runs on your own machine and never sees the contents of your network traffic, and it requires two-factor authentication for every sensitive action. Here's exactly what leaves your machine and what doesn't — no vague reassurances.
What leaves your network — and what doesn't
WatchMyTech is local-first: the app runs entirely on the Windows PC you install it on. To make alerting and the remote portal work, it sends a defined set of data — device status, latency, Active Directory account-change events, and temperature sensor readings — but never the contents of your network traffic, your IP addresses, or any credentials.
Leaves your machine
- Up/down status for each monitored device
- Latency (round-trip time) figures
- A heartbeat confirming the app itself is running
- The name or label you give each monitored device
- Active Directory account-change events — a user created or deactivated, with their name and a timestamp
- Temperature sensor readings, and the sensor labels (from the SensorPush API)
Never leaves your machine
- The contents of your network traffic or packet data
- IP addresses
- Passwords or credentials
Three principles
Two-factor everywhere
TOTP two-factor authentication is enforced at every layer — local app access, system login, and the external portal each require a code. Configuration can only be changed at the PC hosting WatchMyTech.
Outbound-only by design
Communication is passive and one-way. WatchMyTech opens no inbound listener and accepts no remote commands, so it can't be used as a route into your network.
Local-first
Monitoring happens on your own machine. If the connection to our servers drops, local monitoring keeps running — you don't lose visibility of your own network.
The specifics
For anyone assessing WatchMyTech for a client or an internal approval, here's the precise behaviour.
- Telemetry interval
- Status is reported to WatchMyTech's servers every 30 seconds.
- Heartbeat
- A 10-second heartbeat confirms the app is alive and reporting.
- Payload
- Per monitored device: an up/down flag, a latency value, and the device label. Active Directory account-change events and temperature sensor readings are also sent. No network traffic, packet contents, IP addresses, or credentials are included.
- Direction
- Outbound only. No inbound connections are accepted.
- Encryption in transit
- All telemetry is transmitted over HTTPS (TLS).
- Authentication
- TOTP two-factor required for app access, system login, and the external portal.
- Devices per instance
- Up to 30. Run a separate instance per client for independent, isolated monitoring.
Where your data lives
The data held off your machine — device status and latency, Active Directory account-change events, and sensor readings — is stored by the company behind WatchMyTech.
- Operated by
- RECCEIT LTD, a company registered in England & Wales (No. 13400175).
- Hosting location
- United Kingdom. WatchMyTech's servers are hosted in a UK data centre.
- Retention
- Status and latency telemetry is kept for one week, then deleted.
Found a security issue?
If you believe you've found a vulnerability in WatchMyTech, please report it privately so we can fix it before it's made public. Email hello@watchmytech.com with the details and steps to reproduce. We'll acknowledge your report and keep you updated on the fix.
Last updated: November 2026